Oil & Gas Methane Leak Detection

Methane Leak Detection for Oil & Gas Facilities

Locate suspected leak sources, verify CH4 in the field, and monitor high-risk gas wells, valve groups and pipeline stations with a combined handheld inspection and fixed acoustic monitoring solution.

Acoustic imaging TDLAS CH4 verification Fixed acoustic monitoring LDAR workflow support

One application, two working modes

1
Field inspection Use HA3LX during LDAR routes, maintenance inspection and suspected leak confirmation.
2
CH4 verification Use TDLAS methane detection to confirm methane evidence after acoustic localization.
3
Fixed early warning Use HZ-WL-15A at gas wells, valve groups and pipeline stations for continuous alarm workflows.
Application Challenge

Methane leaks are often small, intermittent and hard to confirm.

Methane leaks often happen around valves, flanges, wellheads, compressor areas and pipeline facilities. Some leaks are small, some are intermittent, and some are located in places where manual inspection is difficult or unsafe.

For most oil and gas facilities, one method is not enough. Inspection teams need a handheld tool to find and confirm suspected leaks, while high-risk locations need fixed monitoring for early warning and remote alarm workflows.

  • Find suspected leak points during field inspection.
  • Verify CH4 concentration when methane evidence is needed.
  • Monitor gas wells, valve groups and pipeline stations continuously.
  • Support LDAR, maintenance records and site safety workflows.
methane gas leak localization in an industrial facility using acoustic imaging
Acoustic imaging helps inspection teams see where a suspected leak sound is coming from.
Why It Matters

Turn methane detection into a practical LDAR and safety workflow.

A useful methane leak detection page should not only introduce devices. It should show how the devices help operators discover, confirm, document and respond.

01

LDAR inspection

Support routine leak detection and repair routes with field images, CH4 readings and inspection evidence.

02

Maintenance decisions

Help technicians prioritize valves, flanges, seals and fittings that need repair or follow-up inspection.

03

Fixed early warning

Monitor gas wells, valve groups and remote stations where manual inspection frequency is limited.

04

Data integration

Send alarm data through 4G, Ethernet, HTTP, WebSocket or Modbus TCP to platform and SCADA workflows.

Applications

Typical methane leak detection sites

The same site may need both manual inspection and fixed monitoring. HA3LX is used for inspection rounds. HZ-WL-15A is installed at risk points that need continuous warning.

Gas wells and wellheads

Monitor wellheads, Christmas trees, gas outlets and surrounding pressure equipment.

Valves and flanges

Check valve gaps, flange seals, fittings and pressure control components.

Pipeline stations

Use fixed monitoring around metering stations, valve groups and pressure regulation areas.

LDAR routes

Use HA3LX to support leak detection and repair inspection records.

LNG and gas handling

Inspect LNG/CNG facilities, compressor areas and gas handling equipment.

Remote field sites

Use HZ-WL-15A where manual inspection is limited by distance, staffing or safety conditions.

Two Roles

Handheld inspection and fixed monitoring work together.

Position the solution as a layered deployment: mobile confirmation for inspection teams, and continuous alarm coverage for high-risk fixed points.

HA3LX acoustic and TDLAS methane leak detection camera

HA3LX for inspection teams

Use HA3LX during LDAR routes, plant inspection, LNG site checks and oil and gas maintenance work. It helps users locate the acoustic source first, then verify CH4 concentration with TDLAS.

  • Walk-around methane inspection
  • Gas leak acoustic localization
  • TDLAS methane verification
  • Inspection images and records
HandheldTDLAS CH4LDAR
+
HZ-WL-15A fixed acoustic gas well and valve leak monitoring device

HZ-WL-15A for high-risk points

Use HZ-WL-15A where continuous manual inspection is not practical. It listens for leak-related sound signatures around gas wells, wellhead valves and pipeline stations, then sends alarms to a platform.

  • Fixed acoustic monitoring
  • Gas well and valve monitoring
  • Edge AI local recognition
  • 4G, Ethernet and Modbus TCP
FixedEdge AIRemote alarm
Workflow

Detect, locate, verify, record and alarm.

This replaces the repeated Workflow and How It Works sections with one clearer site workflow for buyers and search engines.

1

Detect

Capture audible or ultrasonic leak-related sound from pressurized components.

2

Locate

Use HA3LX acoustic imaging to show the suspected leak source on screen.

3

Verify

Use TDLAS methane detection to confirm CH4 evidence along the measurement path.

4

Record

Save images, videos, readings and inspection notes for maintenance follow-up.

5

Alarm

Use HZ-WL-15A to monitor fixed points and transmit remote leak alarms.

HA3LX acoustic and TDLAS methane leak detection camera HA3LX TDLAS methane concentration verification during gas leak inspection
Handheld Methane Inspection

HA3LX Acoustic & Methane Laser Camera

HA3LX is for inspection teams who need to walk the site, check suspected leak points and keep inspection evidence. The camera combines acoustic imaging with TDLAS methane detection, so users can locate the leak-related sound source and verify whether methane is present along the measurement path.

144Digital MEMS microphones for acoustic imaging.
TDLASMethane laser detection for CH4 verification.
2 kHz-150 kHzFrequency bandwidth for audible and ultrasonic inspection.
0.3-210 mOperating distance for field inspection.
Fixed Acoustic Monitoring

HZ-WL-15A Gas Well & Valve Leak Monitor

HZ-WL-15A is for locations that need continuous attention but cannot rely only on manual inspection. It captures leak-related acoustic signatures around gas wells, wellhead valves and pipeline stations, analyzes the signal locally, and sends alarms through wired or wireless communication.

9 MEMSAcoustic sensor array for leak signature capture.
20 Hz-80 kHzFrequency range for audible and ultrasonic leak sounds.
Edge AILocal leak recognition and abnormal sound judgment.
4G / EthernetRemote alarm and platform integration.
HZ-WL-15A fixed acoustic gas well and valve leak monitoring device gas well valve group methane leak monitoring field installation
Selection Guide

Choose based on the field task.

This card layout is easier to scan than a wide table, especially on mobile and in Ueeshop page blocks.

Use HA3LX when...

Your team performs walk-around inspection, LDAR routes or troubleshooting after a suspected leak is reported.

  • Locate suspected leak sources acoustically.
  • Verify CH4 with TDLAS on site.
  • Keep images, videos and inspection records.

Use HZ-WL-15A when...

The site needs continuous attention but manual inspection frequency is limited by distance, staffing or safety conditions.

  • Monitor gas wells, valves and pipeline stations.
  • Use edge AI for local abnormal sound recognition.
  • Send alarms to a platform or SCADA workflow.
Field Evidence

Show what buyers actually evaluate.

Use real inspection images, CH4 verification screens and fixed monitoring installation photos to make the page feel field-ready.

FAQ

Common questions

Do I need both HA3LX and HZ-WL-15A?

Not always. Use HA3LX if your main task is field inspection or LDAR. Use HZ-WL-15A if you need continuous monitoring at fixed points such as gas wells, valves or pipeline stations. For high-risk sites, the two products can be used together.

Is HA3LX a methane detector or an acoustic camera?

It is both. HA3LX combines acoustic imaging with TDLAS methane detection, so it can help locate the suspected leak source and verify CH4 concentration.

Where should HZ-WL-15A be installed?

Typical locations include gas wells, wellhead valves, valve groups, pipeline stations and other fixed points where continuous leak monitoring is needed.

How does the solution support LDAR workflows?

HA3LX can be used during LDAR routes to locate suspected leak points, verify CH4 with TDLAS and keep field evidence for maintenance follow-up. HZ-WL-15A can add fixed early warning at high-risk points that need continuous monitoring.

Does acoustic methane detection replace OGI?

It is better to present acoustic imaging, TDLAS methane verification and OGI as complementary methods. Acoustic imaging helps locate leak-related sound sources, TDLAS verifies methane evidence, and OGI can visualize gas plumes under suitable field conditions.

Plan Your Deployment

Need a methane leak detection plan for your facility?

Tell us your facility type, inspection task and monitoring points. HERTZINNO can help you choose between HA3LX handheld inspection, HZ-WL-15A fixed monitoring, or a combined deployment.

For LDAR routesAsk for HA3LX field inspection recommendations.
For fixed pointsPlan monitoring coverage for wells, valves and stations.
For combined sitesBuild a layered inspection and alarm workflow.
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.